Wall Mounted Electric Boiler Advanced Design Technology Electric Heating Furnace Electromagnetic Heating Technology
Precautions for using wall mounted electric boilers:
Improve the thermal insulation of the house. If the house is not well insulated, a large amount of indoor heat will be lost to the outside, and a large amount of cold air will flow into the room. The domestic electric heating furnace will keep heating, and the gas consumption will naturally be large. Therefore, it is necessary to check the sealing performance of doors and windows in advance, reduce the number of opening and closing doors and windows, and pay special attention to blocking the gaps left by the air conditioning pipes, Avoid radiating heat outdoors from some small gaps.
The indoor temperature should be kept appropriate and adjusted to 18 to 20 ℃, too high indoor temperature is easy to cause energy waste. If necessary, the indoor temperature controller can be installed to effectively control the size of the fire through automatic adjustment of the controller, so as to better save the gas consumption. When there is no one at home, the program of economic and energy-saving operation can be adjusted and the function key of antifreeze protection can be set to better ensure that the temperature of domestic electric heating furnace heating water supply is not lower than the antifreeze setting value of 5 ° C.
Wall Mounted Electric Boiler Product Parameters:
Serial number | Product model | Company | LC-B-6kw | LC-B-8kw | LC-B-10kw | LC-B-12kw | LC-B-15kw |
one | Rated power | KW | 6 | 8 | 10 | 12 | 15 |
two | Rated current | A | 27.3 | 36.4 | 45.5 | 48.2 | 52.8 |
three | Heating area | ㎡ | 60-80 | 80-100 | 100-120 | 120-140 | 150-180 |
four | input voltage | 50HZ | 220V | 220V | 220V | 220V/380V | 220V/380V |
five | Minimum flow of water pump configuration | L/min | 15 | 15 | 20 | 20 | 25 |
six | Hot water yield 50 ℃ | L/min | 5.62 | 3.75 | 4.69 | 5.62 | 6.9 |
seven | Design thermal efficiency | ℃ | 98% | 98% | 98% | 98% | 98% |
eight | Maximum water temperature | ℃ | 85 | 85 | 85 | 85 | 85 |
nine | Low temperature protection temperature | ℃ | 5 | 5 | 5 | 5 | 5 |
ten | Overall dimension (length * width * height) | mm | 360*170*630 | 360*170*630 | 360*170*630 | 360*170*630 | 360*170*630 |
13 | Water inlet and outlet interface | DN | 32 | 32 | 32 | 32 | 32 |
First of all, the floor of the room, the orientation of the room, and whether the double-layer insulating glass is used for the insulation of the wall make a great difference in the insulation and heat dissipation of the house. For example, the multi-sided walls of a single villa directly contact the outside for more heat dissipation. If the insulation is not well done, the room needs to reach the same temperature, and the required heat supply may be multiplied. Secondly, the use habits of each family are different. The comfortable temperature required by different families is 2 to 5 ℃, and many families are used to open the window twice in the morning and half an hour in the evening for natural ventilation, which will affect the operation cost.